Define method Vacuum stability test for chemical stability of single base and double base propellants

 

BOJANA FIDANOVSKI

Military Technical Institute, Belgrade, b.fidanovski@gmail.com

MIRJANA dIMIĆ

Military Technical Institute, Belgrade, mirjanadimicjevtic@gmail.com

aLEKSANDAR MILOJKOVIĆ

Military Technical Institute, Belgrade

Nataša karišik

Military Technical Institute, Belgrade

 

Abstract: This paper includes the results of the examination of the single base propellants and double base propellants with Czech Vacuum Stability Test STABIL. For this method the main term was to analyze and define the best options for preparation the samples, selection of the optimal mass of the samples and conditions of examination. Chemical stability of these samples was determined according to the standard method STANAG 4556.

Keywords: Powder, single base propellants, double base propellants, chemical stability, Vacuum stability test.

 

Copyright © OTEH 2012. All rights reserved.  _  oteh@vti.vs.rs